Use this list when you install a Batterieslab battery and hand it over to its owner.
Before installing
- The battery type, capacity and voltage match the system design.
- Every battery of a bank is the same type, capacity and age, and fully charged.
- The location is dry, ventilated, away from heat and direct sun, and within the battery's temperature range.
- The battery is secured so it can't move.
Wiring
- Correct polarity, checked before connecting.
- Cables sized for the maximum current, with proper lugs, and terminals tightened firmly.
- A fuse or breaker on the positive, sized for the cable and the battery.
- In a bank: equal cable lengths, and the bank connected diagonally.
- Series or parallel only as the manual allows.
Charging sources and loads
- Chargers, solar controllers and inverter-chargers set to LiFePO4 or to the battery's voltages; equalisation and temperature compensation off. See Charging.
- No charging from a vehicle's alternator.
Checks with Battery Monitor
- Connect to each battery: no alarm, the cells close together, the temperature normal.
- Charge and discharge briefly: the current shows in the app and nothing trips.
Handover
- The owner installs Battery Monitor and signs in with their own account.
- The owner registers each battery within 30 days of purchase, with the purchase date from the invoice: Registering your battery. Don't register a customer's battery to your own account.
- For an Ermis battery: the owner requests Ermis Cloud access, and the key is entered in the battery's settings page: Ermis.
- The owner keeps the invoice, and knows how to open a support case.
- In the partner portal, the battery is assigned to you as its installer, so you see it and its cases.